Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
ACS Sens ; 8(6): 2159-2168, 2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: covidwho-20245129

RESUMEN

In addition to efficacious vaccines and antiviral therapeutics, reliable and flexible in-home personal use diagnostics for the detection of viral antigens are needed for effective control of the COVID-19 pandemic. Despite the approval of several PCR-based and affinity-based in-home COVID-19 testing kits, many of them suffer from problems such as a high false-negative rate, long waiting time, and short storage period. Using the enabling one-bead-one-compound (OBOC) combinatorial technology, several peptidic ligands with a nanomolar binding affinity toward the SARS-CoV-2 spike protein (S-protein) were successfully discovered. Taking advantage of the high surface area of porous nanofibers, immobilization of these ligands on nanofibrous membranes allows the development of personal use sensors that can achieve low nanomolar sensitivity in the detection of the S-protein in saliva. This simple biosensor employing naked-eye reading exhibits detection sensitivity comparable to some of the current FDA-approved home detection kits. Furthermore, the ligand used in the biosensor was found to detect the S-protein derived from both the original strain and the Delta variant. The workflow reported here may enable us to rapidly respond to the development of home-based biosensors against future viral outbreaks.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Humanos , COVID-19/diagnóstico , Glicoproteína de la Espiga del Coronavirus/química , SARS-CoV-2 , Ligandos , Prueba de COVID-19 , Colorimetría , Pandemias , Péptidos
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 301: 122980, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: covidwho-20231155

RESUMEN

Corona Virus Disease 2019 (COVID-19) as the infectious disease caused the pandemic disease around the world through infection by SARS-CoV-2 virus. The common diagnosis approach is Quantitative RT-PCR (qRT-PCR) which is time consuming and labor intensive. In the present study a novel colorimetric aptasensor was developed based on intrinsic catalytic activity of chitosan film embedded with ZnO/CNT (ChF/ZnO/CNT) on 3,3',5,5'-tetramethylbenzidine (TMB) substrate. The main nanocomposite platform was constructed and functionalized with specific COVID-19 aptamer. The construction subjected with TMB substrate and H2O2 in the presence of different concentration of COVID-19 virus. Separation of aptamer after binding with virus particles declined the nanozyme activity. Upon addition of virus concentration, the peroxidase like activity of developed platform and colorimetric signals of oxidized TMB decreased gradually. Under optimal conditions the nanozyme could detect the virus in the linear range of 1-500 pg mL and LOD of 0.05 pg mL. Also, a paper-based platform was used for set up the strategy on applicable device. The paper-based strategy showed a linear range between 50 and 500 pg mL with LOD of 8 pg mL. The applied paper based colorimetric strategy showed reliable results for sensitive and selective detection of COVID-19 virus with the cost-effective approach.


Asunto(s)
Aptámeros de Nucleótidos , COVID-19 , Óxido de Zinc , Humanos , Peroxidasa/metabolismo , Oxidación-Reducción , Colorimetría/métodos , Peróxido de Hidrógeno/análisis , Biomimética , COVID-19/diagnóstico , SARS-CoV-2 , Aptámeros de Nucleótidos/metabolismo
3.
ACS Appl Mater Interfaces ; 15(16): 20483-20494, 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: covidwho-2297232

RESUMEN

Surface ligands play a critical role in controlling and defining the properties of colloidal nanocrystals. These aspects have been exploited to design nanoparticle aggregation-based colorimetric sensors. Here, we coated 13-nm gold nanoparticles (AuNPs) with a large library of ligands (e.g., from labile monodentate monomers to multicoordinating macromolecules) and evaluated their aggregation propensity in the presence of three peptides containing charged, thiolate, or aromatic amino acids. Our results show that AuNPs coated with the polyphenols and sulfonated phosphine ligands were good choices for electrostatic-based aggregation. AuNPs capped with citrate and labile-binding polymers worked well for dithiol-bridging and π-π stacking-induced aggregation. In the example of electrostatic-based assays, we stress that good sensing performance requires aggregating peptides of low charge valence paired with charged NPs with weak stability and vice versa. We then present a modular peptide containing versatile aggregating residues to agglomerate a variety of ligated AuNPs for colorimetric detection of the coronavirus main protease. Enzymatic cleavage liberates the peptide segment, which in turn triggers NP agglomeration and thus rapid color changes in <10 min. The protease detection limit is 2.5 nM.


Asunto(s)
Colorimetría , Nanopartículas del Metal , Colorimetría/métodos , Oro/química , Nanopartículas del Metal/química , Polímeros , Ligandos
4.
ACS Sens ; 8(4): 1422-1430, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: covidwho-2303906

RESUMEN

Here, quercetin-mediated silver nanoparticle (AgNP) formation combined with loop-mediated isothermal amplification (LAMP) was introduced to colorimetrically detect two major infectious pathogens, SARS-CoV-2 and Enterococcus faecium, using a foldable PMMA microdevice. The nitrogenous bases of LAMP amplicons can readily form a complex with Ag+ ions, and the catechol moiety in quercetin, which acted as a reducing agent, could be chelated with Ag+ ions, resulting in the easy electron transfer from the oxidant to the reductant and producing brown-colored AgNPs within 5 min. The introduced method exhibited higher sensitivity than agarose gel electrophoresis due to more active redox centers in quercetin. The detection limit was attained at 101 copies µL-1 and 101 CFU mL-1 for SARS-CoV-2 RNA and E. faecium, respectively. A foldable microdevice made of two pieces of PMMA that fully integrates DNA extraction, amplification, and detection processes was fabricated to establish practical applicability. On one PMMA, DNA extraction was performed in a reaction chamber inserted with an FTA card, and then LAMP reagents were added for amplification. Silver nitrate was added to the reaction chamber after LAMP. On the other PMMA, quercetin-soaked paper discs loaded in the detection chamber were folded toward the reaction chamber for colorimetric detection. An intense brown color was produced within 5 min when heated at 65 °C. The introduced colorimetric assay, which is highly favorable for laboratory and on-site applications, could be a valuable alternative to conventional methods for detecting infectious diseases, given its unique principle, simplicity, and naked-eye detection.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Nanopartículas del Metal , Humanos , Colorimetría/métodos , Quercetina , Polimetil Metacrilato , ARN Viral , SARS-CoV-2 , Plata , ADN
5.
Anal Chim Acta ; 1257: 341167, 2023 May 29.
Artículo en Inglés | MEDLINE | ID: covidwho-2302415

RESUMEN

The world is in a long pandemic period caused by the SARS-CoV-2 virus and massive diagnostic tests to assist efforts to control the spread of the disease and also to avoid new coronavirus variants are still needed. Herein, we propose a simple and accurate saliva-based colorimetric test for the diagnosis of COVID-19. Magnetic beads (MBs) modified with a sequence of single-strand DNA (ssDNA) complementary to the N gene of the SARS-CoV-2 RNA were developed and used for magnetic capture and separation from a complex saliva sample. A second biotinylated ssDNA sequence was applied, and the colorimetric detection was carried out by adding streptavidin-horseradish peroxidase conjugate, H2O2, and tetramethylbenzidine (TMB) as chromogenic substrate. The test does not require viral RNA isolation, transcription, or amplification steps and can be performed at room temperature. The molecular assay test can be run using 96-well microplates, allowing the diagnosis of a large number of samples in 90 min. A simple support for magnets was designed and constructed using a 3D printer that allows the magnetic separations directly in the 96-well microplate. The colorimetric test showed an excellent ability to discriminate between healthy individuals and patients infected with SARS-CoV-2, with 92% and 100% of clinical sensitivity and specificity, respectively. This performance was similar to that achieved using the gold standard RT-PCR technique. The proposed genomagnetic assay offers an opportunity to greatly increase population testing, contribute to controlling the spread of the virus, and improve health equity in testing for COVID-19.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , Prueba de COVID-19 , ARN Viral/genética , Colorimetría/métodos , Sensibilidad y Especificidad , Técnicas de Amplificación de Ácido Nucleico/métodos
6.
Anal Chim Acta ; 1255: 341102, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2288795

RESUMEN

Although many approaches have been developed for the quick assessment of SARS-CoV-2 infection, few of them are devoted to the detection of the neutralizing antibody, which is essential for assessing the effectiveness of vaccines. Herein, we developed a tri-mode lateral flow immunoassay (LFIA) platform based on gold-silver alloy hollow nanoshells (Au-Ag HNSs) for the sensitive and accurate quantification of neutralizing antibodies. By tuning the shell-to-core ratio, the surface plasmon resonance (SPR) absorption band of the Au-Ag HNSs is located within the near infrared (NIR) region, endowing them with an excellent photothermal effect under the irradiation of optical maser at 808 nm. Further, the Raman reporter molecule 4-mercaptobenzoic acid (MBA) was immobilized on the gold-silver alloy nanoshell to obtain an enhanced SERS signal. Thus, these Au-Ag HNSs could provide colorimetric, photothermal and SERS signals, with which, tri-mode strips for SARS-CoV-2 neutralizing antibody detection were constructed by competitive immunoassay. Since these three kinds of signals could complement one another, a more accurate detection was achieved. The tri-mode LFIA achieved a quantitative detection with detection limit of 20 ng/mL. Moreover, it also successfully detected the serum samples from 98 vaccinated volunteers with 79 positive results, exhibiting great application value in neutralizing antibody detection.


Asunto(s)
Anticuerpos Neutralizantes , COVID-19 , Inmunoensayo , Nanocáscaras , SARS-CoV-2 , Espectrometría Raman , Humanos , Aleaciones , Anticuerpos Neutralizantes/inmunología , Anticuerpos Neutralizantes/aislamiento & purificación , Anticuerpos Antivirales/inmunología , Colorimetría/métodos , COVID-19/diagnóstico , COVID-19/inmunología , Oro , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Nanopartículas del Metal , SARS-CoV-2/inmunología , Plata , Espectrometría Raman/métodos
7.
ACS Appl Mater Interfaces ; 15(9): 12327-12338, 2023 Mar 08.
Artículo en Inglés | MEDLINE | ID: covidwho-2287610

RESUMEN

Timely, accurate, and rapid diagnosis of SARS-CoV-2 is a key factor in controlling the spread of the epidemic and guiding treatments. Herein, a flexible and ultrasensitive immunochromatographic assay (ICA) was proposed based on a colorimetric/fluorescent dual-signal enhancement strategy. We first fabricated a highly stable dual-signal nanocomposite (SADQD) by continuously coating one layer of 20 nm AuNPs and two layers of quantum dots onto a 200 nm SiO2 nanosphere to provide strong colorimetric signals and enhanced fluorescence signals. Two kinds of SADQD with red and green fluorescence were conjugated with spike (S) antibody and nucleocapsid (N) antibody, respectively, and used as dual-fluorescence/colorimetric tags for the simultaneous detection of S and N proteins on one test line of ICA strip, which can not only greatly reduce the background interference and improve the detection accuracy but also achieve a higher colorimetric sensitivity. The detection limits of the method for target antigens via colorimetric and fluorescence modes were as low as 50 and 2.2 pg/mL, respectively, which were 5 and 113 times more sensitive than those from the standard AuNP-ICA strips, respectively. This biosensor will provide a more accurate and convenient way to diagnose COVID-19 in different application scenarios.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Colorimetría/métodos , Oro/química , Dióxido de Silicio , Nanopartículas del Metal/química , Colorantes , Anticuerpos , Inmunoensayo/métodos
8.
Commun Biol ; 6(1): 233, 2023 03 02.
Artículo en Inglés | MEDLINE | ID: covidwho-2283223

RESUMEN

Sensitive and rapid point-of-care assays have been crucial in the global response to SARS-CoV-2. Loop-mediated isothermal amplification (LAMP) has emerged as an important diagnostic tool given its simplicity and minimal equipment requirements, although limitations exist regarding sensitivity and the methods used to detect reaction products. We describe the development of Vivid COVID-19 LAMP, which leverages a metallochromic detection system utilizing zinc ions and a zinc sensor, 5-Br-PAPS, to circumvent the limitations of classic detection systems dependent on pH indicators or magnesium chelators. We make important strides in improving RT-LAMP sensitivity by establishing principles for using LNA-modified LAMP primers, multiplexing, and conducting extensive optimizations of reaction parameters. To enable point-of-care testing, we introduce a rapid sample inactivation procedure without RNA extraction that is compatible with self-collected, non-invasive gargle samples. Our quadruplexed assay (targeting E, N, ORF1a, and RdRP) reliably detects 1 RNA copy/µl of sample (=8 copies/reaction) from extracted RNA and 2 RNA copies/µl of sample (=16 copies/reaction) directly from gargle samples, making it one of the most sensitive RT-LAMP tests and even comparable to RT-qPCR. Additionally, we demonstrate a self-contained, mobile version of our assay in a variety of high-throughput field testing scenarios on nearly 9,000 crude gargle samples. Vivid COVID-19 LAMP can be an important asset for the endemic phase of COVID-19 as well as preparing for future pandemics.


Asunto(s)
COVID-19 , Zinc , Humanos , Colorimetría , COVID-19/diagnóstico , SARS-CoV-2/genética , Cartilla de ADN , Iones
9.
Biosensors (Basel) ; 13(3)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: covidwho-2259062

RESUMEN

One of the emerging technologies in molecular diagnostics of the last two decades is the use of gold nanoparticles (AuNPs) for biosensors. AuNPs can be functionalized with various biomolecules, such as nucleic acids or antibodies, to recognize and bind to specific targets. AuNPs present unique optical properties, such as their distinctive plasmonic band, which confers a bright-red color to AuNP solutions, and their extremely high extinction coefficient, which makes AuNPs detectable by the naked eye even at low concentrations. Ingenious molecular mechanisms triggered by the presence of a target analyte can change the colloidal status of AuNPs from dispersed to aggregated, with a subsequent visible change in color of the solution due to the loss of the characteristic plasmonic band. This review describes how the optical properties of AuNPs have been exploited for the design of plasmonic biosensors that only require the simple mixing of reagents combined with a visual readout and focuses on the molecular mechanisms involved. This review illustrates selected examples of AuNP-based plasmonic biosensors and promising approaches for the point-of-care testing of various analytes, spanning from the viral RNA of SARS-CoV-2 to the molecules that give distinctive flavor and color to aged whisky.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Nanopartículas del Metal , Humanos , Anciano , Oro , SARS-CoV-2 , Colorimetría
10.
Biosensors (Basel) ; 13(1)2022 Dec 26.
Artículo en Inglés | MEDLINE | ID: covidwho-2246528

RESUMEN

Infectious pathogens cause severe threats to public health due to their frightening infectivity and lethal capacity. Rapid and accurate detection of pathogens is of great significance for preventing their infection. Gold nanoparticles have drawn considerable attention in colorimetric biosensing during the past decades due to their unique physicochemical properties. Colorimetric diagnosis platforms based on functionalized AuNPs are emerging as a promising pathogen-analysis technique with the merits of high sensitivity, low-cost, and easy operation. This review summarizes the recent development in this field. We first introduce the significance of detecting pathogens and the characteristics of gold nanoparticles. Four types of colorimetric strategies, including the application of indirect target-mediated aggregation, chromogenic substrate-mediated catalytic activity, point-of-care testing (POCT) devices, and machine learning-assisted colorimetric sensor arrays, are systematically introduced. In particular, three biomolecule-functionalized AuNP-based colorimetric sensors are described in detail. Finally, we conclude by presenting our subjective views on the present challenges and some appropriate suggestions for future research directions of colorimetric sensors.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Oro/química , Nanopartículas del Metal/química , Colorimetría/métodos , Técnicas Biosensibles/métodos
11.
Small ; 19(20): e2208167, 2023 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2241393

RESUMEN

Fluorescence-based PCR and other amplification methods have been used for SARS-CoV-2 diagnostics, however, it requires costly fluorescence detectors and probes limiting deploying large-scale screening. Here, a cut-price colorimetric method for SARS-CoV-2 RNA detection by iron manganese silicate nanozyme (IMSN) is established. IMSN catalyzes the oxidation of chromogenic substrates by its peroxidase (POD)-like activity, which is effectively inhibited by pyrophosphate ions (PPi). Due to the large number of PPi generated by amplification processes, SARS-CoV-2 RNA can be detected by a colorimetric readout visible to the naked eye, with the detection limit of 240 copies mL-1 . This conceptually new method has been successfully applied to correctly distinguish positive and negative oropharyngeal swab samples of COVID-19. Colorimetric assay provides a low-cost and instrumental-free solution for nucleic acid detection, which holds great potential for facilitating virus surveillance.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Colorimetría/métodos , ARN Viral/genética , Técnicas de Amplificación de Ácido Nucleico/métodos
12.
Biosensors (Basel) ; 13(2)2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2238776

RESUMEN

Even with the widespread uptake of vaccines, the SARS-CoV-2-induced COVID-19 pandemic continues to overwhelm many healthcare systems worldwide. Consequently, massive scale molecular diagnostic testing remains a key strategy to control the ongoing pandemic, and the need for instrument-free, economic and easy-to-use molecular diagnostic alternatives to PCR remains a goal of many healthcare providers, including WHO. We developed a test (Repvit) based on gold nanoparticles that can detect SARS-CoV-2 RNA directly from nasopharyngeal swab or saliva samples with a limit of detection (LOD) of 2.1 × 105 copies mL-1 by the naked eye (or 8 × 104 copies mL-1 by spectrophotometer) in less than 20 min, without the need for any instrumentation, and with a manufacturing price of <$1. We tested this technology on 1143 clinical samples from RNA extracted from nasopharyngeal swabs (n = 188), directly from saliva samples (n = 635; assayed by spectrophotometer) and nasopharyngeal swabs (n = 320) from multiple centers and obtained sensitivity values of 92.86%, 93.75% and 94.57% and specificities of 93.22%, 97.96% and 94.76%, respectively. To our knowledge, this is the first description of a colloidal nanoparticle assay that allows for rapid nucleic acid detection at clinically relevant sensitivity without the need for external instrumentation that could be used in resource-limited settings or for self-testing.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , Colorimetría , Saliva , ARN Viral , SARS-CoV-2 , Oro , Pandemias , Nasofaringe , Manejo de Especímenes
13.
Talanta ; 256: 124320, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2221396

RESUMEN

The SARS-CoV-2-related Corona Virus Disease 2019 (COVID-19) epidemic has had a significant negative impact on society and endangered global health. To quickly stop and constrain the pandemic, a SARS-CoV-2 detection technology that is sensitive, quick and reasonably priced is urgently required. The widely used reverse-transcription polymerase chain reaction (RT-PCR) requires complex equipment and a fair amount of time. Reverse transcription-loop-mediated isothermal amplification (RT-LAMP) exhibits significant advantage for early detection of COVID-19 without the requirement for expensive equipment by amplifying a little amount of RNA to a detectable level at isothermal condition. Here, a water-soluble polythiophene-based colorimetric method by combining with RT-LAMP is established for fast and sensitive detection of SARS-CoV-2 RNA. The proposed assay has benefits for the quick detection of SARS-CoV-2 RNA at concentrations as low as 10 aM, or 6 copies/µL.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2/genética , ARN Viral/genética , ARN Viral/análisis , Colorimetría/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Agua , Sensibilidad y Especificidad
14.
Int J Infect Dis ; 128: 285-289, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: covidwho-2210481

RESUMEN

OBJECTIVES: During the third wave, the growing number of COVID-19 case clusters reported countrywide in Thailand demonstrated the rapidly evolving characteristics of SARS-CoV-2, the causative agent of the COVID-19 pandemic. The rapid spread of COVID-19 infections had been extensively reported in public areas and construction camps, as well as in congested communities with poor sanitation. High demand for SARS-CoV-2 genome testing and quick reporting by an hour for case identification and isolation characterizes the COVID-19 crisis in Thailand. This situation leads to an urgent need for alternative molecular tests which are reliable, rapid, and cost-effective. METHODS: In this study, we assessed colorimetric reverse transcription loop-mediated isothermal amplification (RT-LAMP), using real-time reverse transcription-polymerase chain reaction (RT-PCR) as a reference standard, for active case finding in suspected (mostly asymptomatic) cases living in high-risk areas of Bangkok. RESULTS: The diagnostic performance of the RT-LAMP compared with real-time RT-PCR in specimens from 549 Thais were computed in a real-world field study setting. Our study demonstrated that RT-LAMP achieved robust identification of SARS-CoV-2 infection, with a diagnostic sensitivity and specificity of 91.67% and 100%, respectively. CONCLUSION: RT-LAMP is a reliable assay for SARS-CoV-2 detection and is scalable for use in the emergency response to a nationwide pandemic, despite resource limitations. The RT-LAMP real-world data derived from this field study validate its potential use in laboratory practice. RT-LAMP is a good choice as a laboratory-based SARS-CoV-2 molecular test when real-time RT-PCR is not available.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Transcripción Reversa , Pandemias , Colorimetría , Tailandia , Técnicas de Diagnóstico Molecular , Técnicas de Amplificación de Ácido Nucleico , Sensibilidad y Especificidad , ARN Viral/genética
15.
Talanta ; 256: 124271, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: covidwho-2183603

RESUMEN

Rapid screening of multiple pathogens will greatly improve the efficiency of pandemic prevention and control. Colorimetric methods exhibit the advantages of convenience, portability, low cost, time efficiency, and free of sophisticated instruments, yet usually have difficulties in simultaneous detection and suffer from monotonous color changes with low visual resolution and sensitivity. Hence, coupled three kinds of plasmonic nanoparticles (NPs) with magnetic separation, we developed an achromatic colorimetric nanosensor with highly enhanced visual resolution for simultaneous detection of SARS-CoV-2, Staphylococcus aureus, and Salmonella typhimurium. The achromatic nanosensor was composed of SARS-CoV-2-targeting red gold NPs, S. aureus-targeting yellow silver NPs and S. typhimurium-targeting blue silver triangle NPs mixed as black color. In the detection, three corresponding magnetic probes were added into the above mixture. In the presence of a target pathogen, it would be recognized and combined with corresponding colored reporters and magnetic probes to form sandwich complexes, which were removed by magnetic separation, and the sensor changed from black to a chromatic color (the color of the reporters remained in supernatant). Consequently, different target pathogen induced different color. For example, SARS-CoV-2, S. aureus, and S. typhimurium respectively produced green, purple, and orange. While coexistence of S. aureus and S. typhimurium produced red, and coexistence of S. aureus and SARS-CoV-2 produced blue, etc. Therefore, by observing the color change or measuring the absorption spectra, multiple pathogen detection was achieved conveniently. Compared with most colorimetric sensors, this achromatic nanosensor involved rich color change, thus significantly enhancing visual resolution and inspection sensitivity. Therefore, this sensor opened a promising avenue for efficient monitoring and early warning of food safety and quality.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Nanopartículas , Humanos , Plata , Colorimetría/métodos , Staphylococcus aureus , COVID-19/diagnóstico , SARS-CoV-2 , Oro , Fenómenos Magnéticos
16.
Molecules ; 28(2)2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2166753

RESUMEN

Favipiravir (FAV) has become a promising antiviral agent for the treatment of COVID-19. Herein, a green, fast, high-sample-throughput, non-instrumental, and affordable analytical method is proposed based on surfactant-assisted dispersive liquid-liquid microextraction (SA-DLLME) combined with thin-layer chromatography-digital image colourimetry (TLC-DIC) for determining favipiravir in biological and pharmaceutical samples. Triton X-100 and dichloromethane (DCM) were used as the disperser and extraction solvents, respectively. The extract obtained after DLLME procedure was spotted on a TLC plate and allowed to develop with a mobile phase of chloroform:methanol (8:2, v/v). The developed plate was photographed using a smartphone under UV irradiation at 254 nm. The quantification of FAV was performed by analysing the digital images' spots with open-source ImageJ software. Multivariate optimisation using Plackett-Burman design (PBD) and central composite design (CCD) was performed for the screening and optimisation of significant factors. Under the optimised conditions, the method was found to be linear, ranging from 5 to 100 µg/spot, with a correlation coefficient (R2) ranging from 0.991 to 0.994. The limit of detection (LOD) and limit of quantification (LOQ) were in the ranges of 1.2-1.5 µg/spot and 3.96-4.29 µg/spot, respectively. The developed approach was successfully applied for the determination of FAV in biological (i.e., human urine and plasma) and pharmaceutical samples. The results obtained using the proposed methodology were compared to those obtained using HPLC-UV analysis and found to be in close agreement with one another. Additionally, the green character of the developed method with previously reported protocols was evaluated using the ComplexGAPI, AGREE, and Eco-Scale greenness assessment tools. The proposed method is green in nature and does not require any sophisticated high-end analytical instruments, and it can therefore be routinely applied for the analysis of FAV in various resource-limited laboratories during the COVID-19 pandemic.


Asunto(s)
COVID-19 , Microextracción en Fase Líquida , Surfactantes Pulmonares , Humanos , Tensoactivos , Colorimetría , Cromatografía en Capa Delgada , Microextracción en Fase Líquida/métodos , Teléfono Inteligente , Pandemias , Solventes , Cromatografía Líquida de Alta Presión , Lipoproteínas , Preparaciones Farmacéuticas , Límite de Detección
17.
Sci Rep ; 12(1): 21424, 2022 Dec 11.
Artículo en Inglés | MEDLINE | ID: covidwho-2160322

RESUMEN

The coronavirus pandemic accentuated the need for molecular diagnostic tests. A technique highly used to this end is the Polymerase Chain Reaction (PCR)-a sensitive and specific technique commonly used as the gold standard for molecular diagnostics. However, it demands highly trained personnel and high-maintenance equipment and is relatively time-consuming. An alternative is the Loop-Mediated Isothermal Amplification (LAMP) technique, which doesn't need sample purification or expensive equipment, and is similar to PCR when compared in sensitivity and specificity. In this paper, we developed an optimized colorimetric Reverse Transcriptase Loop-Mediated Isothermal Amplification (RT-LAMP) Point-of-Care test using a portable device to diagnose COVID-19. Variables such as concentration of primers, magnesium sulfate, betaine, hydrochloride guanidine, Bst, and temperature of the reactions were tested. We also created a pipetting quality control system-using a combination of dyes-to avoid false negatives due to a lack of samples added to the reaction test tube. Mineral oil was incorporated in the composition of the RT-LAMP reactions to avoid evaporation when a heating lid isn't available. The final RT-LAMP test is tenfold more sensitive when compared to the WarmStart Colorimetric Master mix from New England Biolabs with a sensitivity of 5 copies per µL.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular , Colorimetría
18.
Carbohydr Polym ; 302: 120368, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: covidwho-2120305

RESUMEN

The rapidly growing electronic and plastic waste has become a global environmental concern. Developing advanced and environmentally safe agro-based materials is an emerging field with an enormous potential for applications in sensors and devices. Here, an agro-based material as membrane has been developed by incorporating tapioca starch and banana peel powder in polylactic acid, with uniform dispersibility and amorphous nature. The material was used for the development of electrochemical sensor for S-gene of SARS-CoV-2. Further, the membrane was used for the development of a non-invasive, colorimetric skin patch for the detection of glucose and a sensor for the assessment of fruit juice quality. Using OECD-recommended model systems, the developed membrane was found to be non-toxic towards aquatic and terrestrial non-target organisms. The developed conductive material opens new avenues in various electrochemical, analytical, and biological applications.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Manihot , Musa , Musa/química , Colorimetría , COVID-19/diagnóstico , SARS-CoV-2 , Almidón/química
19.
J Pharm Biomed Anal ; 222: 115087, 2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2095683

RESUMEN

The current pandemic of the acute severe respiratory syndrome coronavirus 2 (SARS-CoV-2) killed about 6.4 million and infected more than 600 million individuals by august of 2022, and researchers worldwide are searching for fast and selective approaches for this virus detection. Colorimetric biosensors are an excellent alternative because they are sensitive, simple, fast, and low-cost for rapid detection of SARS-CoV-2 compared to standard Enzyme-linked immunosorbent assay (ELISA) and Polymerase Chain Reaction (PCR) techniques. This study systematically searched and reviewed literature data related to colorimetric biosensors in detecting SARS-CoV-2 viruses, recovered from the Scopus (n = 16), Web of Science (n = 19), PubMed (n = 19), and Science Direct (n = 17) databases totalizing n = 71 articles. Data were analyzed for the type of nanomaterial, biorecognition material at the detection limit (LOD), and devices designed for diagnostics. The most applied nanomaterial were gold nanoparticles, in their original form and hybrid in quantum dots and core-shell. In addition, we show high specificity in point-of-care (POC) diagnostic devices as a faster and cheaper alternative for clinical diagnosis. Finally, the highlights of the colorimetric biosensor developed for diagnostic devices applied in swabs, surgical masks, and lateral flow immunoassays were presented.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Humanos , SARS-CoV-2 , Colorimetría , Oro , COVID-19/diagnóstico
20.
Analyst ; 147(24): 5613-5622, 2022 Dec 05.
Artículo en Inglés | MEDLINE | ID: covidwho-2087332

RESUMEN

Two lineages (BA.1 and BA.2) of the Omicron variant are the main ones responsible for the recent COVID-19 pandemic waves worldwide. Monitoring the prevalence and spread of these variants is important as the presence of mutations might lower the efficacy of vaccines and hinder the benefits of monoclonal antibody therapies. Although the need to screen these new lineages is emerging, genetic sequencing is scarce due to its high cost. Alternatively, we propose using reverse transcription loop-mediated isothermal amplification (RT-LAMP) to infer the prevalence of these lineages and aid in genomic surveillance in countries with limited genetic sequencing capacity. For this, we designed specific primers and tested them on a panel of 267 sequenced RNA genomes from different lineages. The test for BA.1 and its descendants showed 96.63% sensitivity, 100% specificity, and 98.85% accuracy, and the test for BA.2 and descendants showed 90.00% sensitivity, 98.85% specificity, and 98.52% accuracy. These results demonstrate the potential of RT-LAMP to be an alternative to help monitor variants, especially in countries with scarce resources.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Colorimetría , Pandemias , COVID-19/diagnóstico , Técnicas de Amplificación de Ácido Nucleico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA